Search results for "Neutron dosimetry"
showing 7 items of 7 documents
Application of Electron Spin Resonance technique in neutron dosimetry
2012
Along with the Neutron Capture Therapy (NCT) development and with the use of thermal neutrons for radiotherapeutic purposes, many efforts have been devoted to the beam characterization in order to optimize the therapy procedures. Reliable dosimetric measurements should be able to determine the various components (neutronic and photonic) of the mixed beam usually employed for therapy [1]. We have studied the effect of the additive such as gadolinium and 10B-boric acid on the neutron sensitivity of alanine ESR dosimeters exposed to a gamma and mixed (n, gamma) field mainly composed by thermal neutrons. We have chosen both this additive nuclei because of their very high capture cross section t…
CHARACTERIZATION OF THE GAMMA DOSE COMPONENT IN THE NEUTRON FIELD OF A BNCT IRRADIATION FACILITY
2017
At the University of Pavia, a neutron irradiation facility has been constructed for preclinical in vitro and in vivo studies for BNCT. The facility is a wide channel (40 x 20 x 100 cm3) inside the graphite Thermal Column of the 250 KW research reactor TRIGA Mark II. The neutron field consists in a thermal component ranging from about 1010 and 109 cm-2s-1 along the longitudinal axis of the channel and it is uniform within 10% along the transversal axes. The fast neutron contamination (En > 1.58 keV) is more than 2 orders of magnitude lower. The gamma background coming from the core has been reduced with a 20 cm thick bismuth shield, however in the facility a gamma component is still prese…
Neutron dosimetry by means of electron spin resonance (ESR) tecnique
2012
Along with the Neutron Capture Therapy (NCT) development and with the use of thermal neutrons for radiotherapeutic purposes, many efforts have been devoted to the beam characterization in order to optimize the therapy procedures. Reliable dosimetric measurements should be able to determine the various components (neutronic and photonic) of the mixed beam usually employed for therapy. We have studied the effect of the additive such as gadolinium and 10B-boric acid on the neutron sensitivity of alanine ESR dosimeters exposed to a gamma and mixed (n, gamma) field mainly composed by thermal neutrons. We have chosen both this additive nuclei because of their very high capture cross section to th…
Neutron ESR dosimetry through ammonium tartrate with low Gd content.
2014
This paper continues analyses on organic compounds for application in neutron dosimetry performed through electron spin resonance (ESR). Here, the authors present the results obtained by ESR measurements of a blend of ammonium tartrate dosemeters and gadolinium oxide (5 % by weight). The choice of low amount of Gd is due to the need of improving neutron sensitivity while not significantly influencing tissue equivalence. A study of the effect of gadolinium presence on tissue equivalence was carried out. The experiments show that the neutron sensitivity is enhanced by more than an order of magnitude even with this small additive content. Monte Carlo simulations on the increment of energy rele…
Neutron–gamma mixed field measurements by means of MCP–TLD600 dosimeter pair
2007
Abstract In this paper, we compared the TL response of three types of thermoluminescence dosimeters, TLD600 (6LiF:Mg,Ti), TLD700 (7LiF:Mg,Ti) and MCP (LiF:Mg,Cu,P) after exposure to a n–γ mixed field in the fluence range of radiotherapeutic applications. Since a dosimeter pair is required to discriminate the two components of the mixed field, we analyzed the ability of each dosimeter pair to provide the fluence value in the mixed field. At this aim we performed a 60Co–γ calibration and a neutron calibration for all three dosimeter types. Finally, a blind test was performed in order to analyze the accuracy of each dosimeter pair and we found that in this mixed field the fluence value obtaine…
Use of 70 MeV proton beam for medical applications at INFN-LNS: CATANA project
2000
The project CATANA (Centro di Adro Terapia ed Applicazioni Nucleari Avanzate) is a collaboration between the INFN-Laboratori Nazionali del Sud (LNS), Physics Department, Ophthalmology Institute and Radiology Institute of the Catania University and CSFNSM Catania. The main goal of CATANA is the study and the application of protontherapy for the treatment of shallow tumors (4 cm max) like uveal melanomas and subfoveal macular degenerations.
Dosimetry to Electron Spin Resonance (ESR) using organic compounds (alanine and ammonium tartrate) for mixed neutron-gamma fields
2015
Alongside with the development of Neutron Capture Therapy (NCT) and the use of thermal neutrons for radiotherapeutic purposes, many efforts have been devoted to the characterization of the beam in order to optimize therapy procedures. Reliable dose measurements should be able to determine the various (neutrons and photonic) components of the mixed beam usually employed for therapy. This paper studies the effect of additives such as Boric and Gadolinium nuclei on the sensitivity of neutron organic (alanine and ammonium tartrate) dosimeters analyzed through Electron Spin Resonance (ESR) technique. These dosimeters were exposed to a mixed (neutron-gamma) field mainly composed of thermal neutro…